A high-flow nasal cannula (HFNC) system delivers a heated, humidified air-oxygen mixture through a wide-bore nasal cannula at flows far above standard oxygen therapy (this listing specifies 2 to 70 L/min), with the oxygen concentration set independently of the flow. Heating and humidification make high flows comfortable and protect the lining of the airway.

High-Flow Nasal Cannula (HFNC) Respiratory System price

Starting fromUS$2,100+ shipping

Starting price for a new unit, updated November 2026. Shipping is extra; configuration and quantity affect the final quote.

Product details and specifications

ParameterSpecification
System functionBlends air and oxygen, regulates oxygen concentration and provides active humidification
Public catalogue example (not a confirmed MedPrax configuration)2–70 L/min flow range, heated humidification, touchscreen FiO₂ control and integrated battery backup are available on a manufacturer system
Exact flow range, FiO₂ range, humidifier settings, patient interfaces and batteryConfirm for the supplied model
BrandMedPrax
Classification
HFNCHigh Flow Nasal CannulaRespiratory HumidifierOxygen TherapyCritical Care
Clinical Applications
Supplies to
GlobalIndiaMiddle EastAfricaSoutheast AsiaEuropeNorth America

Technical and clinical details

Key Features and Capabilities

  • Air-oxygen blending: electronic blending sets the delivered oxygen fraction (FiO2), typically from 21% up to 100%, independent of flow.
  • Active heated humidification: a heated humidifier chamber and heated breathing tube deliver gas close to body temperature and fully saturated, preventing dry mucosa and condensation in the tube.
  • High flow: flushes exhaled carbon dioxide from the upper airway and adds a small positive airway pressure.
  • Interfaces: adult, paediatric and neonatal nasal cannulas in several sizes; many systems also connect to tracheostomy interfaces.
  • Alarms and battery: confirm flow, FiO2, temperature and circuit alarms, and battery backup for transfers within the hospital.

Clinical Applications

HFNC is used for acute hypoxaemic respiratory failure such as pneumonia, after extubation to lower the risk of re-intubation, for pre-oxygenation before intubation, for patients who do not tolerate a face mask, and for breathlessness in palliative care. Paediatric and neonatal units use it for bronchiolitis and as an alternative to nasal CPAP in selected babies.

Technical Specifications and Highlights

Listed flow range: 2 to 70 L/min. Confirm the FiO2 range, humidifier temperature settings, patient interfaces included, oxygen inlet pressure, battery runtime and whether a compressed-air supply is needed for the supplied model.

Recommended Settings and Environments

ICUs, HDUs, emergency departments and respiratory wards, and step-down units that want to avoid escalating to non-invasive or invasive ventilation. Plan for an oxygen supply that can sustain high flows on every HFNC bed. See the ventilator price guide for related respiratory equipment.

Summary

Running costs are mostly single use: a heated breathing circuit, humidifier chamber and nasal cannula per patient, plus sterile water. Compare quotes on the device price and the consumable cost per patient. MedPrax Market can quote HFNC systems with adult, paediatric or neonatal consumables.

Detailed specifications

Product overview A high-flow nasal cannula respiratory system combines electronic air-oxygen blending, active humidification and oxygen-concentration regulation. The listing specifies a flow range of 2–70 L/min. It supplies a controlled air-oxygen mixture through a nasal interface with humidification for prescribed respiratory therapy. Listed specifications No model-specific technical specifications are included in the current listing. Details to confirm The listing does not include a complete model-specific datasheet. Request the current manufacturer documentation to confirm the exact configuration, dimensions, performance, compatibility and supplied accessories.

Enquire about the High-Flow Nasal Cannula (HFNC) Respiratory System

Tell us your quantity and site requirements and we will confirm pricing, configuration and delivery. MedPrax can also help with technical sizing, financing and customs.

Regulatory evidence and documentation

Evidence applies to the stated device, scope and jurisdiction. A reviewed document does not establish approval for every destination or configuration.

Supplier-provided labels · not independently verified

CE, ISO

Compliance and import notes

Documentation to confirm

Regional topics (Global): FDA, CE, local regulatory, CDSCO

These regional topics are procurement prompts, not certifications or claims about this listing. Confirm destination requirements against the product-specific evidence above.

Indicative import context (Global)

Tax context
Varies by destination
Customs / duty context
Confirm GST and customs

Indicative only. Tax, duty, and classification vary by product, destination, exemptions, and importer of record. Confirm before purchase.